IPM production and storage hall with measurement technology and loading equipment in Gotha
Service area South-eastern Europe

Pile testing in Albania

Static and dynamic load testing, integrity testing and consulting from the planning stage. Test force up to 40,000 kN.

Ground conditions

What the ground in Albania demands

Soft coastal sediments on the Adriatic plain, flysch and limestone inland. The region is seismically active, which places additional demands on foundations and verification.

Transport structures, port facilities, energy and building construction.

Codes

Project-specific test concepts, usually per Eurocode 7 and DIN EN ISO 22477.

Recommended method

Static load test. Up to 40,000 kN, own loading platform and beam system.

Project inquiry

Request a project

Tell us the project, the number of piles and the planned test load. You will receive a test concept with a quote within two business days.