IPM production and storage hall with measurement technology and loading equipment in Gotha
Service area Baltic region

Pile testing in Latvia

Static and dynamic load testing, integrity testing and consulting from the planning stage. Test force up to 40,000 kN.

Ground conditions

What the ground in Latvia demands

Soft marine and glacial sediments along the coast, underlain by dolomite and sandstone. High groundwater levels shape installation and testing.

Transport structures, port facilities, building construction in coastal areas.

Codes

Eurocode 7 with the Latvian National Annex, DIN EN ISO 22477.

Recommended method

Static load test. Up to 40,000 kN, own loading platform and beam system.

Project inquiry

Request a project

Tell us the project, the number of piles and the planned test load. You will receive a test concept with a quote within two business days.