IPM production and storage hall with measurement technology and loading equipment in Gotha
Pile testing Berlin

Pile testing in Berlin

Load testing and integrity testing for Berlin and Brandenburg. Own measurement technology, test force up to 40,000 kN, travel distance about 3 hours from Gotha.

Ground conditions

What Berlin is founded on.

Berlin sits on the Warsaw-Berlin glacial valley: boulder clay, sands of varying density, embedded peat and mud lenses, plus a high groundwater level. Density changes over short distances, exploration points on a 30 metre grid do not show the same picture.

What happens without testing

Design based on experience values is often too far on the safe side here, in peat lenses too far on the unsafe side. Both look the same on paper. Settlement differences between neighbouring piles are the reason structures crack.

Untested foundations are not a cost risk, they are a structural stability risk. Differential settlement, cracking and re-foundation cost many times the price of testing.

Typical construction tasks: Inner-city densification, additional storeys on existing foundations, transport structures, high-rise projects on the water.

Methods

Three methods, one decision.

In Berlin and Brandenburg the ground often leads to static load test. We make the final choice based on the ground report and pile concept, not on instinct.

Dynamic load test in Berlin

Bearing capacity of several piles within one day, evaluated per CAPWAP. The method per DIN EN ISO 22477-4 delivers shaft friction and base resistance separately and fits where the construction schedule does not allow a week of setup.

Drop weight up to 12 t, evaluation per CAPWAP

Static load test in Berlin

The direct proof per DIN EN ISO 22477-1. The load-settlement line shows the real load behaviour under sustained load, up to 40,000 kN test force. Basis for foundation optimisation and for any disputed proof.

Up to 40,000 kN, own loading platform and beam system

Integrity test in Berlin

Test of construction quality: length, cross-section, necking, defects. Low-strain from the pile head for the whole site, cross-hole between measuring tubes for the core of large bored piles.

Low-strain and cross-hole, large quantities

Regional answers

Questions on pile testing in Berlin

All questions on process, methods, standards and scheduling are in the FAQ section.

Pile testing in Berlin

A soil survey and pile concept are enough for a reliable answer. Travel distance about 3 hours from Gotha.

Project inquiry

Request a project

Tell us the project, the number of piles and the planned test load. You will receive a test concept with a quote within two business days.